What is intumescent paint?
Intumescent paint is a thin-film fire protective coating. It looks like ordinary paint, but when it is exposed to fire it swells into a thick insulating char. The char slows how fast the steel heats up, so the structure keeps carrying its load for longer and occupants and fire crews get more time.
Because it finishes like paint, intumescent coating is the go-to choice for exposed steel where appearance matters: feature columns, beams in foyers and retail spaces, balconies, mezzanines and architectural steel. Ary Fire is a specialist passive fire contractor based in Cronulla. We are the applicator, not a product supplier: we prepare, coat, measure and certify the steel ourselves.
Our intumescent coating services
Structural steel
Intumescent coating to UB, UC, SHS, RHS, CHS, PFC and angle sections on new builds, fit-outs and refurbishments. The dry film thickness for each member is taken from the system's loading table for its section factor and the FRL in your fire engineering report or BCA design.
Galvanised lintels and shelf angles
Fire rating of galvanised lintels and shelf angles supporting brickwork, using systems assessed for application over galvanising.
Surface preparation and priming
Sandblasting and priming where the system needs it, or compatibility checks over existing primers, so the coating bonds properly and performs as tested.
Workshop or on-site application
We can coat steel in the workshop before erection to save time on site, or apply on site with airless spray, brush or roller, then touch up connections after install.
Topcoats
Decorative topcoats in your chosen colour, or protective topcoats such as safety yellow for warehouses and carparks.
Timber and bushfire
Exfire Fireshell F1E for exterior timber in BAL-12.5, BAL-19 and BAL-29 areas, and Fireshield TimberClear and TimberWhite for Group 1 interior timber and structural timber up to 60 minutes FRR.
Systems we apply
| Systems | Nullifire SC900, PPG Steelguard 851, Cafco Sprayfilm WB3, Firetex, CAP508 |
|---|---|
| FRL range | 30 to 120 minutes, depending on section factor and system |
| Substrates | Structural steel, galvanised steel, plasterboard, timber, cabling and pressed metal |
| Standards | Tested to AS 1530.4, steel design to AS 4100, compliance with the NCC |
| Handover | DFT report and installation certificate for the certifier and passive fire register |
How an intumescent job runs
- Take-off: we measure every member from your structural drawings and work out section factors.
- Specification: we select the system and set the dry film thickness for each section from the loading table.
- Preparation: sandblasting, priming or compatibility checks, and masking of surrounding work.
- Application: coats built up by airless spray, brush or roller, with wet film checks as we go.
- Inspection: dry film thickness readings at each test location, recorded against the required DFT.
- Certification: DFT report and installation certificate stating the product, system, FRL and members treated.
Recent intumescent coating projects
A few of the jobs our crew has completed. See the full projects page for more.
Latest job: steel lift frame, Mount Street, Coogee
Intumescent painting to a new multi-level structural steel lift frame at a Coogee home. Our crew worked from scaffold, built the intumescent coating to the specified dry film thickness on every column, beam, rail and connection, and finished it smooth white ready to stay exposed. More jobs in Coogee and the eastern suburbs.







Other intumescent work includes Rhodes Stage 2 for Billbergia (preparation, priming and coating to steel brackets), Sydney Water at Rouse Hill (fire-rated steel brackets), Imperio Constructions in Rose Bay (galvanised lintels supporting brickwork) and structural steel for Hutchison Builders in Sydney.
Intumescent painting for steel fire rating
Steel fire rating is about keeping structural steel below its critical temperature for the fire resistance level the building needs. Intumescent paint does that with a thin coating: in a fire it expands up to many times its applied thickness and forms an insulating char around the steel. The thickness needed depends on the section size, how many sides are exposed and the FRL, so every intumescent coating we apply is specified per member from the product's assessment data.
Builders, fabricators and owners use Ary Fire as their intumescent paint contractor because we do the whole scope ourselves: take-off, system selection, surface preparation, priming, intumescent painting to the specified DFT, topcoat and certification. We apply intumescent coating on site from scaffold and EWPs, or in the fabricator's workshop before the steel is erected.
Intumescent paint or vermiculite fire spray?
Intumescent is the better choice for exposed steel where the finish matters, because it looks like normal paint. Vermiculite fire spray is usually cheaper for steel hidden in ceilings and voids, for ducts and soffits, and for FRLs above 120 minutes. We do both, so we will recommend the system that suits your steel. Read our guide on intumescent paint vs vermiculite fire spray.
Why builders use Ary Fire for intumescent coatings
- Specialist passive fire contractor: we apply the coating, we are not a paint supplier.
- Take-offs done from your drawings, so quotes are based on measured quantities.
- Dry film thickness read and recorded on every member.
- Workshop or on-site application to suit your program.
- DFT report and installation certificate for your certifier and passive fire register.
- Fire spray and fire stopping available on the same job.
Areas we cover
We work across Sydney, including the CBD, Mascot, Coogee and the eastern suburbs, Sutherland Shire, Parramatta, Penrith, Campbelltown, Blacktown and Liverpool, plus regional NSW, Canberra and Melbourne. Local pages: fire protection Parramatta passive fire Sutherland Shire and Mascot, Green Square and Coogee.
Common questions
What is intumescent paint?
Intumescent paint is a thin-film fire protective coating that looks like ordinary paint but swells into an insulating char in a fire. The char slows how fast steel heats up, so the structure keeps its load-bearing capacity for the required fire resistance period.
What FRL can intumescent paint achieve?
Typically 30 to 120 minutes on structural steel, depending on the section factor of each member and the system used. The dry film thickness for each member comes from the system's loading table.
Can intumescent paint go over galvanised steel?
Yes, using a system assessed for galvanised substrates, with the right surface preparation and primer. We regularly coat galvanised lintels, shelf angles and posts.
Can you apply intumescent paint in the workshop?
Yes. We can coat steel in the workshop before erection to save time on site, then touch up connections and damage after install.
Do you provide a DFT report and installation certificate?
Yes. Every job is handed over with dry film thickness readings and an installation certificate stating the product, system, FRL and members treated, ready for your certifier and passive fire register.
How much does intumescent painting cost?
It depends on the steel sizes, the FRL, surface preparation, access and whether the work is in the workshop or on site. Send your structural drawings and we will come back with a take-off and a fixed price.
Need steel fire rated with intumescent?
Send your structural drawings or a few photos. We'll come back with a take-off, a fixed quote and a DFT report and installation certificate at handover.